Using the no-op true command on other paths to that disk, will cause GEOM to re-”taste” the disk and see the label and automatically add the additional paths to the existing multipath. This will write a GEOM Multipath label to the last sector of the disk. Each SAS Expander will present as a new /dev/ses# device, so your system may have more than one.
I agree to receive your newsletters and accept the data privacy statement. Ensure device health & easy replacements with these valuable tips. Discover strategies to manage disk arrays on FreeBSD and related platforms/operating systems. Simply installing the apps and choosing a pool for k3s and docker creates a dataset and logs. Your pool gets writes from somewhere and ZFS is writing those to disk every 5 seconds.

RustDesk Remote Desktop

It’s hard to imagine why your drives are that loud! It’s a datacenter drive, very loud, so it’s still audible. For quietness, a noise reducing case, move it somewhere else, quieter drives, maybe SSD instead of hard drives, etc.

What is AnyDesk and what is it used for?

SAS disk reservations provide the ability to connect to the disk redundantly—or even across multiple machines—while ensuring it is only used by one of them at a time. SAS provides many more features than SATA does—including full duplex operations, advanced error recovery, multipath, and disk reservations. It too was an extension on an existing interface bus which offered greatly improved performance. SATA+AHCI improved data transfer speeds, simplicity of communication, and included abilities that we today take for granted, such as “hot swap” and command queueing. These concepts also apply to other operating systems, but the tools might differ slightly.

Help & Info about AnyDesk for Windows

For ZFS users, automating fault responses with tools like ZED (ZFS Event Daemon) can simplify disk replacement and minimize downtime. Configuring your system to notify you when a disk has errors, or when the filesystem reports a degraded device, will ensure your system gets prompt attention when something goes wrong. Experienced enterprise storage managers also keep extensive notes including the model number, SKU and/or URL for reordering, purchase order information, warranty end date, warranty URL, and any other useful information about each drive. While the operating system typically provides device aliases based on the disk’s serial number, WWN, or some other static identifier, this does not provide all of the information you might want.

Recommended Recovery Tools

I will optimize settings later for the security/quietness tradeoff however, I’m very pleased with it for now. How can I set this value on the Truenas interface? Keeping it spinning but not accessing data is safer. I would still recommend against idling your drive as that reduces longevity. I also set the tunable vfs.zfs.txg.timeout to a somewhat large value so the regular syncs don’t happen every 5 seconds.
If your system has multipath SAS, each disk will be present more than once, and you should use the gmultipathcommand to deduplicate your disks and for labeling as well. FreeBSD supports a number of different ways to label the disk, depending on your use case. The map command displays all of the SES devices and each element (this is the nomenclature in SES) connected to them. Of course, all of this chassis management technology isn’t very effective without tools to make it usable. It also provides information about each slot in the enclosure (even if empty), including a flag to indicate if the device has recently been swapped.
Unnamed devices can be specified by their specific SES device and element number. This greatly reduces the chance of getting it wrong when you (or the datacenter technician) physically pulls the disk. You can also reboot, and GEOM will pick up the multipath when it first tastes the disks during boot.

  • This will write a GEOM Multipath label to the last sector of the disk.
  • With modern, especially Enterprise grade hard drives being able to have hundreds of thousands of head park operations in their service life, is this really an isssue?
  • I gave up and just built a Windows Storage Space with tiering and the drives are now effectively silent.
  • The parking rate basically drops to zero at the time I updated the settings for the Seagate drives, and the Western Digital one hasn’t changed because it needs to be powered off to change that setting and I haven’t done so yet.
  • Disk vendors typically provide their own vendor-specific ways to do persistent configuration of power management settings, so it’s worth trying to use those instead so the desired configuration doesn’t depend on the host system applying it, instead being configured in the drive (but in some cases it might be desirable to have the host configure that!).
  • Somewhat more useful for monitoring is the smartmon_load_cycle_count_raw_value, which provides the actual number of load cycles that have been done.
  • The total throughput possible from the connected disks is still limited by the number of lanes available, but this is likely the best approach in systems with more than a dozen disks.

Truenas Scale disk activity every few seconds when idle

The settings you mentioned are already set this way. After you apply these settings the logs will be written to your SSD instead of being flushed to the disc array. Those are probably the system logs being flushed to disk every few seconds. I have moved the system data to my boot SSDs, don’t have any apps installed and don’t have any pool set for reveryplay apps.
FreeBSD’s sesutil is a tool to interface with the SES devices on your system. You should also configure smartd to monitor your disks and send you alerts, which may give you advanced notice when a drive is starting to fail. These special boards, called SAS Expanders, reduce the total cabling required to provide power and signal pathways to all connected disks.

The APM specification dating from 1992 includes some controls for hard drives, allowing a host system to specify the desired performance level of a disk and whether standby is permitted by sending commands to a disk. In addition to the above query types, SES also supports a number of commands, including activating the “locate” and “fault” LEDs if present, and the ability to individually power off drives. The first step is to map out the relationship between the physical chassis where the disks reside, and the logical devices enumerated by the operating system.
Sounds like the drives being woken for the ZIL to flush writes to the ZFS pool and then going back to idle/sleep every 5 seconds. Enable the checkmark for the Syslog and choose a pool that is not based on hard drives. I had this same problem, using HGST data center refurb drives.
Unfortunately, APM settings don’t persist between power cycles so if we wanted to change disk settings with APM they would need to be reapplied on every boot. Advanced power management levels80h and higher do not permit the device to spin down to save power. For example, a device may implement one power management method from 80h to A0h and a higherperformance, higher power consumption method from level A1h to FEh. To prevent parking more often that is useful (for a server, usually that choice would be “very rarely”), there are a couple ways to do it and which apply will depend on what the hard drive vendor’s firmware supports. With the SMART metrics captured by Prometheus, it’s fairly easy to write a query that will show how often a given disk is parking its heads. Since I use Prometheus to capture information on the server’s operation however, I can use that to monitor that my hard drives are doing well.

  • You should also configure smartd to monitor your disks and send you alerts, which may give you advanced notice when a drive is starting to fail.
  • At a glance, changing idle3 and EPC settings seems to have done the job nicely; here is the same graph of head park rates per disk as before, but on a smaller timescale that makes individual head parks visible.
  • This partitions each disk and labels the ZFS partition with the enclosure, slot, and serial number of the corresponding disk.
  • For example, a device may implement one power management method from 80h to A0h and a higherperformance, higher power consumption method from level A1h to FEh.
  • The timer values specified are in milliseconds, so this example will park the disk heads after 30 minutes of inactivity.
  • I guess it depends on the drives, but don’t think you’ll find any software solution.

My question is – is there a way to tell if a certain disk suffers from the issue prior to purchasing? For the system I’m monitoring here, the SSD that it boots from has a wearout indicator sitting on 95 of 100 (only 5% of the rated life consumed), visibly unchanged for a long time so it’s not very interesting as an example. (The properties like ID_SERIAL_SHORT can be queried on a running system using udevadm info, such as udevadm info /dev/sdd to get the properties of the disk currently assigned ID sdd.) Somewhat more useful for monitoring is the smartmon_load_cycle_count_raw_value, which provides the actual number of load cycles that have been done. Secondly what are your disk monitoring refresh intervals and what do you use on your system to monitor SMART disk health?
For chassis with larger numbers of drives, or when connecting external JBOD chassis, it is common for the drives to connect to a specialized board that provides power and routing for the SATA/SAS signals to the controller. When building a storage system, there are many different ways the disks might be connected to the system. NVME-oF allows storage devices and arrays in remote chassis to be connected to local motherboards. NVMe storage comes in many form factors, from small M.2 devices to U.2 and other hot-swappable formats intended for servers. NVMe connects storage devices directly to the PCIe bus, offering extremely low latency and high throughput.
Whether you are a computer technician in charge of technical support or a student who needs to work together with their classmates, AnyDesk is the program you are looking for. Then, click on “Connect” to access the other device. Send it to the other user who has the program and they will be able to access and control your device. It is very popular among professionals who provide technical support. Remember, the key is to act quickly and use the right tools for your specific situation. These practices and tools should give you a solid starting point for recovering your deleted files.
Other interfaces for remote storage include iSCSI, Fiber-Channel, Infiniband, RoCE, and others, but those specialized solutions are beyond the scope of this article. Serial Attached SCSI (SAS) is the most common interface for enterprise storage, first appearing in 2004. Serial ATA (SATA) is the familiar interface used for non-enterprise storage, and is an extension of the original ATA interface dating from the 1980s. In this article we will discuss some strategies and tools to make managing disk arrays on FreeBSD (and related platforms like TrueNAS Core) much easier. It may be what you want is to enable HDD standby, which will “spin down” the drives when not in use